Deal of The Day! Hurry Up, Grab the Special Discount - Save 25% - Ends In 00:00:00 Coupon code: SAVE25
Welcome to Pass4Success

- Free Preparation Discussions

Oracle 1Z0-1091-22 Exam

Exam Name: Oracle Utilities Meter Solution Cloud Service 2022 Implementation Professional
Exam Code: 1Z0-1091-22
Related Certification(s): Oracle Cloud Certification
Certification Provider: Oracle
Actual Exam Duration: 90 Minutes
Number of 1Z0-1091-22 practice questions in our database: 51 (updated: May. 10, 2024)
Expected 1Z0-1091-22 Exam Topics, as suggested by Oracle :
  • Topic 1: Generate TOU map data and check for correctness/ Describe Measurement Reprocessing functionality and Substractive Interval Data
  • Topic 2: Implement Best practices for measurement retention/ Describe the commands generally supported by SGG adapters and the Adapter Development Kit (ADK)
  • Topic 3: Describe Service Order Management and Service Investigative Orders/ Configure Device Events to support filtering of momentary outage events
  • Topic 4: Describe and implement intial measurements, final measurements, and derrived values/ Configure Service Points, Devices and Measuring Components and Measurement Cycles
  • Topic 5: Smart Grid Gateway (SGG) SaaS Overview, Adapters and Integrations/ Explain the cloud service payload processing configuration
  • Topic 6: Explain key concepts Service Points, Devices and Measuring Components/ Configure VEE rules and exceptions, including the VEE rules used by the consumption synchronization process
  • Topic 7: Configure the Smart Grid Gateway (SGG) SaaS Architecture/ Configure specifications and their relationship to assets
  • Topic 8: Explain the key concepts of Time-of-Use (TOU) and how it applies to final measurements/ Explain the main components of Dynamic Aggregations
  • Topic 9: Design and set up the admin data required to effectively configure a usage subscription/ Service Points, Devices and Measuring Components
  • Topic 10: Configure base package usage calculation rules/ Map Interval Measurements To Time-of-Use Periods/ Smart Grid Gateway (SGG) SaaS Payload Processing
Disscuss Oracle 1Z0-1091-22 Topics, Questions or Ask Anything Related

Currently there are no comments in this discussion, be the first to comment!

Free Oracle 1Z0-1091-22 Exam Actual Questions

Note: Premium Questions for 1Z0-1091-22 were last updated On May. 10, 2024 (see below)

Question #1

Which THREE statements are true about the Subtractive Interval Data functionality?

Reveal Solution Hide Solution
Correct Answer: A, B, C

The Subtractive Interval Data functionality is a feature that enables Meter Data Management (MDM) to process interval data from devices that do not provide interval readings, but only cumulative readings. The Subtractive Interval Data functionality performs the following actions:

The IMD load processes calculate consumption in engineering units: The IMD load processes are batch processes that load initial measurement data (IMD) records from smart meter systems or other sources into MDM. The IMD load processes calculate consumption in engineering units by subtracting consecutive cumulative readings and applying conversion factors.

A new reading condition field ensures that you do not lose the reading quality when a meter's consumption is estimated: A reading condition field is an attribute that indicates the quality or status of a measurement, such as valid, invalid, estimated, or substituted. A new reading condition field called Original Reading Condition is added to store the original reading condition of a cumulative reading when its consumption is estimated by using VEE rules.

You can optionally validate for rollover exceptions and negative consumption calculations: You can configure VEE rules to check for rollover exceptions and negative consumption calculations when processing subtractive interval data. A rollover exception occurs when a cumulative reading reaches its maximum value and resets to zero. A negative consumption calculation occurs when a cumulative reading decreases instead of increasing.

It is not true that it validates consumption in initial measurement data (IMD), which are records that store the raw measurement data that is received from smart meter systems or other sources. Subtractive Interval Data functionality does not validate consumption in IMD, but calculates consumption from cumulative readings.

It is not true that it converts engineering units into reads, which are values that are recorded by devices at certain intervals or events. Subtractive Interval Data functionality does not convert engineering units into reads, but calculates consumption in engineering units from cumulative readings.


Question #2

The interval proxy day estimation Validation, Estimation, and Editing (VEE) rule estimates missing intervals by selecting interval data to average from a list of days that are most like the day being estimated. This is achieved by measuring the component comparison periods.

What is used to define the proxy?

Reveal Solution Hide Solution
Correct Answer: B

The interval proxy day estimation VEE rule is a rule that estimates missing intervals by selecting interval data to average from a list of days that are most like the day being estimated. This is achieved by measuring the component comparison periods, which are periods of time that are used to compare different days based on certain criteria. According to the Oracle Utilities Meter Data Management Business User Guide, one factor that is used to define the proxy or the list of days that are most like the day being estimated is:

Weather data: This is data that indicates the temperature or other weather conditions for a given day. Weather data can be used to select days that have similar weather patterns or variations as the day being estimated.


Question #3

Your client requests you to design and set up data necessary to support an electric meter that is installed at a customer's service point with solar panels:

* Channel 1: Measures the kWh that was consumed from the grid. This is an interval channel that measures in 60-minute intervals.

* Channel 2: Measures the kWh that was generated. This is an interval channel that measures in 60-minute intervals.

Using the Math usage rule, you must create usage transactions that take the difference between the consumed and generated channels, store and name the difference value, and store the derived curve.

Which THREE statements are true?

Reveal Solution Hide Solution
Correct Answer: A, B, C

The client requests to design and set up data necessary to support an electric meter that is installed at a customer's service point with solar panels. The meter has two channels that measure the kWh that was consumed from the grid and the kWh that was generated. Using the Math usage rule, usage transactions that take the difference between the consumed and generated channels must be created and stored. According to the Oracle Utilities Meter Data Management Business User Guide, some statements that are true about this scenario are:

The two channels need distinct service quantity identifiers (SQIs) to differentiate between the generated and consumed kWh. SQIs are codes that identify different types of usage data, such as kWh, kVARh, or kW. SQIs can be used to specify which usage data should be used for calculation or validation purposes.

Net consumption SQI is required. This is a code that identifies the usage data that represents the difference between the consumed and generated kWh. Net consumption SQI can be used to store and name the difference value and export it to other systems.

You must set ''Save Derived Vector'' to Yes in the Math usage rule. This is a parameter that indicates whether the derived curve that results from the Math usage rule should be saved or not. Setting this parameter to Yes can be used to store the derived curve that represents the net consumption.


Question #4

Devices are often added to Meter Data Management (MDM) via a synchronization process. Device configuration business objects (BOs) can be configured to use Synchronization Add BO to determine the appropriate BO for the new device.

What is Synchronization Add BO associated with?

Reveal Solution Hide Solution
Correct Answer: D

Synchronization Add BO is associated with the lifecycle algorithm on Dl-Device Configuration BO. A lifecycle algorithm is a custom logic that can be developed by using Groovy scripting language or Java programming language. A lifecycle algorithm is used to perform certain actions or validations when a business object is created, updated, or deleted. Synchronization Add BO is a parameter that can be configured on the lifecycle algorithm on Dl-Device Configuration BO. Synchronization Add BO is used to determine the appropriate business object for creating a new device based on certain criteria, such as device type or device configuration type.

Synchronization Add BO is not associated with the business service associated with Dl-Device Configuration BO, which is a component that provides the functionality and logic for processing data related to device configuration. Synchronization Add BO is not associated with the options on Dl-Device Configuration BO, which are configurable values that can be used to define business rules or relationships for device configuration. Synchronization Add BO is not associated with the validation algorithm on Dl-Device Configuration BO, which is a custom logic that can be developed by using Groovy scripting language or Java programming language. A validation algorithm is used to perform certain checks or validations on the data entered for device configuration.


Question #5

Your client requests you to design and set up data necessary to support an electric meter that is installed at a customer's service point with solar panels:

* Channel 1: Measures the kWh that was consumed from the grid. This is an interval channel that measures in 60-minute intervals.

* Channel 2: Measures the kWh that was generated. This is an interval channel that measures in 60-minute intervals.

Using the Math usage rule, you must create usage transactions that take the difference between the consumed and generated channels, store and name the difference value, and store the derived curve.

Which THREE statements are true?

Reveal Solution Hide Solution
Correct Answer: A, B, C

The client requests to design and set up data necessary to support an electric meter that is installed at a customer's service point with solar panels. The meter has two channels that measure the kWh that was consumed from the grid and the kWh that was generated. Using the Math usage rule, usage transactions that take the difference between the consumed and generated channels must be created and stored. According to the Oracle Utilities Meter Data Management Business User Guide, some statements that are true about this scenario are:

The two channels need distinct service quantity identifiers (SQIs) to differentiate between the generated and consumed kWh. SQIs are codes that identify different types of usage data, such as kWh, kVARh, or kW. SQIs can be used to specify which usage data should be used for calculation or validation purposes.

Net consumption SQI is required. This is a code that identifies the usage data that represents the difference between the consumed and generated kWh. Net consumption SQI can be used to store and name the difference value and export it to other systems.

You must set ''Save Derived Vector'' to Yes in the Math usage rule. This is a parameter that indicates whether the derived curve that results from the Math usage rule should be saved or not. Setting this parameter to Yes can be used to store the derived curve that represents the net consumption.



Unlock Premium 1Z0-1091-22 Exam Questions with Advanced Practice Test Features:
  • Select Question Types you want
  • Set your Desired Pass Percentage
  • Allocate Time (Hours : Minutes)
  • Create Multiple Practice tests with Limited Questions
  • Customer Support
Get Full Access Now

Save Cancel
az-700  pass4success  az-104  200-301  200-201  cissp  350-401  350-201  350-501  350-601  350-801  350-901  az-720  az-305  pl-300  

Warning: Cannot modify header information - headers already sent by (output started at /pass.php:70) in /pass.php on line 77