Deal of The Day! Hurry Up, Grab the Special Discount - Save 25% - Ends In 00:00:00 Coupon code: SAVE25
Welcome to Pass4Success

- Free Preparation Discussions

Oracle Exam 1Z0-076 Topic 1 Question 11 Discussion

Actual exam question for Oracle's 1Z0-076 exam
Question #: 11
Topic #: 1
[All 1Z0-076 Questions]

Examine the Data Guard configuration:

Which three will be true after a successful failover to Cats?

Show Suggested Answer Hide Answer
Suggested Answer: B, D, E

After a successful failover to the 'cats' database in a Data Guard configuration:

B: Sheep, being another standby database, would typically remain in the enabled state unless specifically disabled or if there was a configuration issue.

D: Dogs, which was the primary database prior to failover, will be in a disabled state as part of the failover process. Manual intervention is required to re-establish 'dogs' as a standby database or to return it to the primary role through another role transition.

E: If the configuration was in Maximum Availability mode before failover, it would remain in this mode after failover, provided all settings were properly configured and no changes were made to the protection mode.

Option A is incorrect because failover does not automatically change the protection mode to Maximum Performance. The protection mode remains as it was prior to the failover unless manually altered.


Contribute your Thoughts:

Judy
11 months ago
I disagree, I believe it's A, B, and D.
upvoted 0 times
...
Ruthann
11 months ago
I think the correct answers are A, C, and E.
upvoted 0 times
...
Gilberto
11 months ago
I bet the person who wrote this question has a dog named Sheep and a cat named Dogs. That's the only way this makes sense!
upvoted 0 times
Howard
10 months ago
D) Dogs will be in the disabled state and has to be manually reinstated.
upvoted 0 times
...
Vincent
10 months ago
B) Sheep will be in the enabled state.
upvoted 0 times
...
Lyla
10 months ago
A) The configuration will be in Maximum Performance mode.
upvoted 0 times
...
...
Emogene
11 months ago
I'm not sure about B and C. Does that mean Sheep will be in the opposite state after the failover? This question is tricky!
upvoted 0 times
...
Abel
11 months ago
Hmm, I think D and E are the correct answers. The configuration will be in Maximum Availability mode after the failover, and Dogs will need to be manually reinstated.
upvoted 0 times
Carmelina
10 months ago
Yes, the configuration will be in Maximum Availability mode after the failover. Sheep will be in the disabled state.
upvoted 0 times
...
Vesta
10 months ago
I agree, D and E are the correct answers. Dogs will need to be manually reinstated after the failover.
upvoted 0 times
...
Princess
10 months ago
Yes, Dogs will be in the disabled state and will need to be manually reinstated after the failover.
upvoted 0 times
...
Fletcher
11 months ago
User 2
upvoted 0 times
...
Shaun
11 months ago
I agree, D and E are the correct answers.
upvoted 0 times
...
Kristel
11 months ago
User 1
upvoted 0 times
...
...

Save Cancel
az-700  pass4success  az-104  200-301  200-201  cissp  350-401  350-201  350-501  350-601  350-801  350-901  az-720  az-305  pl-300  

Warning: Cannot modify header information - headers already sent by (output started at /pass.php:70) in /pass.php on line 77