After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP 9.8 software.

In this scenario, what is causing this problem?

Show Suggested Answer Hide Answer
Suggested Answer: A, C

Contribute your Thoughts:

Fausto
9 days ago
Firmware mismatch, eh? That's always a pain to troubleshoot. Gotta love it when the cluster interconnect switches don't play nice.
upvoted 0 times
...
Wei
10 days ago
Hmm, the adapter card issue could definitely be the culprit here. Looks like they didn't do their homework on the supported configurations.
upvoted 0 times
...
Izetta
25 days ago
I believe we should also check for any NXOS firmware mismatch as mentioned in the Interoperability Matrix.
upvoted 0 times
...
Keena
27 days ago
I agree with Johnna, the 10 Gbps to 10 Gbps cluster Interconnect could be causing the problem.
upvoted 0 times
...
Johnna
29 days ago
I think the issue might be with the cluster Interconnect speed mismatch.
upvoted 0 times
...
Fredric
1 months ago
Mixing node models is never a good idea, especially with a major version upgrade like 9.8. This is probably the root cause of the problem.
upvoted 0 times
Mammie
8 days ago
D) There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supported version.
upvoted 0 times
...
Georgene
11 days ago
C) The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
upvoted 0 times
...
Bernardine
15 days ago
A) The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
upvoted 0 times
...
...
Cecily
1 months ago
The speed mismatch between the AFF A300 and AFF A700 nodes is definitely causing the latency issues. I'm surprised they didn't catch that during the expansion.
upvoted 0 times
...