Your customer experienced some problems caused by outdated HPE Superdome Flex firmware. Which update method should they use to avoid these issues in the future?
HPE System Update Manager (SUM) is the recommended method for updating firmware on HPE Superdome Flex systems, especially when HPE Persistent Memory firmware needs to be updated. HPE SUM ensures that all firmware components are updated correctly and consistently, reducing the risk of compatibility issues.
One of the administrators added some connections within a server profile that was created using a template. This server profile did not report inconsistency.
What is the most likely reason for this behavior?
An administrator tries to open iLO interlace from HPE OneView Instead of being automatically logged in a login prompt displays
Where should you start the troubleshooting process?
When the iLO interface prompts for a login instead of automatically logging in via HPE OneView, a common issue is that the Single Sign-On (SSO) certificate might have been removed or is not properly configured on the iLO. Verifying the presence and validity of the SSO certificate on the iLO interface is a critical step in troubleshooting this issue.
Your customer plans to add four HPE Synergy frames to an existing management ring Ail installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.
Which statement about mixing different FLM modules is true?
In HPE Synergy, a management ring can indeed contain mixed frame link module (FLM) configurations. This means you can have a mix of 2-port and 4-port FLM modules within the same management ring without needing to replace the existing 2-port modules. This flexibility allows for gradual upgrades and scalability within the management ring.
Your customer plans to expand an existing nPar based on a single HPE Superdome Flex chassis. Which statement about workload availability during expansion is true?
HPE Superdome Flex allows for the expansion of powered-on nPars (nPartitions), but this capability is subject to certain conditions. One of these conditions is that the nPar does not use HPE Persistent Memory. Expanding an nPar with Persistent Memory typically requires a shutdown to reconfigure the memory settings safely.
Freeman
8 days agoLilli
2 months agoLenora
2 months agoHershel
3 months agoStevie
3 months agoFelix
3 months agoCeola
4 months agoTrinidad
4 months agoRaina
4 months agoJesusa
5 months agoKendra
5 months agoChu
5 months agoStefanie
5 months agoLaurel
6 months agoTheodora
6 months agoWai
6 months agoSherell
6 months agoHan
6 months agoKate
7 months agoCecily
7 months agoLavonna
7 months agoLinwood
7 months agoTeddy
7 months agoJudy
8 months agoBrandon
8 months agoZona
8 months agoShaquana
8 months agoLynda
8 months agoHoney
9 months agoSharee
9 months agoKing
9 months agoDierdre
9 months agoFrederica
9 months agoWenona
10 months agoCarmen
10 months agoSocorro
11 months agoLuisa
11 months agoMichell
11 months agoNakita
12 months agoYolando
12 months agoArtie
1 years agoTheola
1 years ago