Independence Day Deal! Unlock 25% OFF Today – Limited-Time Offer - Ends In 00:00:00 Coupon code: SAVE25
Welcome to Pass4Success

- Free Preparation Discussions

Citrix Exam 1Y0-312 Topic 1 Question 65 Discussion

Actual exam question for Citrix's 1Y0-312 exam
Question #: 65
Topic #: 1
[All 1Y0-312 Questions]

Scenario: A Citrix Engineer is working on an existing Citrix Virtual Apps and Desktops environment with two Delivery Controllers each in Primary zone and Secondary zone located in two different datacenters respectively. Due to an outage in the Primary zone datacenter, both Delivery Controllers in the Primary zone failed to start.

Which three statements will be true in this scenario? (Choose three.)

Show Suggested Answer Hide Answer
Suggested Answer: B

Contribute your Thoughts:

Silva
1 months ago
Wait, is there a joke about Delivery Controllers not delivering on their promises? I feel like I'm missing something here.
upvoted 0 times
...
Paris
1 months ago
Looks like I need to brush up on my Citrix failover knowledge. This is a tricky scenario!
upvoted 0 times
...
Benedict
1 months ago
I'm feeling a little nervous about this one. I hope the existing sessions in the primary zone don't get disconnected, that would be a nightmare!
upvoted 0 times
Alethea
13 days ago
A) Site performance will increasingly degrade until the Delivery Controllers in the Primary zone become available.
upvoted 0 times
...
...
Raul
1 months ago
Oh, I definitely know that Studio won't be able to connect to the site if the primary Delivery Controllers are down. That's a no-brainer!
upvoted 0 times
Jose
11 days ago
C: Connections to Virtual Delivery Agent (VDA) machines in the Primary zone cannot be made either.
upvoted 0 times
...
Alex
14 days ago
B: Existing sessions in the Primary zone will be disconnected as well.
upvoted 0 times
...
Edelmira
1 months ago
A: Yeah, Studio definitely won't be able to connect to the site without the primary Delivery Controllers.
upvoted 0 times
...
...
Catina
2 months ago
Hmm, I'm pretty sure connections to the VDAs in the secondary zone will still be possible. That's the whole point of a secondary zone, right?
upvoted 0 times
Claudia
1 months ago
D) Connections to Virtual Delivery Agent (VDA) machines in the Primary zone cannot be made.
upvoted 0 times
...
Jovita
1 months ago
B) Connections to Virtual Delivery Agent (VDA) machines in the Secondary zone cannot be made.
upvoted 0 times
...
Shala
1 months ago
A) Site performance will increasingly degrade until the Delivery Controllers in the Primary zone become available.
upvoted 0 times
...
...
Carlota
2 months ago
Whoa, this is a tricky one! With the primary zone down, I bet the users are going to be scrambling to get their work done.
upvoted 0 times
Dawne
2 months ago
E) Existing sessions in the Primary zone will be disconnected.
upvoted 0 times
...
Malinda
2 months ago
B) Connections to Virtual Delivery Agent (VDA) machines in the Secondary zone cannot be made.
upvoted 0 times
...
Paris
2 months ago
A) Site performance will increasingly degrade until the Delivery Controllers in the Primary zone become available.
upvoted 0 times
...
...
Carlton
2 months ago
But if the Delivery Controllers in the Primary zone are down, how can connections to VDA machines in the Primary zone be made?
upvoted 0 times
...
Marguerita
2 months ago
I disagree, I believe B, C, and E are the correct statements.
upvoted 0 times
...
Carlton
2 months ago
I think A, D, and E are true.
upvoted 0 times
...

Save Cancel
az-700  pass4success  az-104  200-301  200-201  cissp  350-401  350-201  350-501  350-601  350-801  350-901  az-720  az-305  pl-300  

Warning: Cannot modify header information - headers already sent by (output started at /pass.php:70) in /pass.php on line 77